All of our pumping units come with a unique Pumping Unit Inspection Report that will give you insight into the operational capability of the pumping unit. Before asking for a pumping unit quote, please make sure to look over this inspection report to make sure it fits the needs of your oilfield project. If you are in need of additional equipment, please make sure to look at our inventory list or contact us for the most up-to-date list available.
Pumping Unit Information
MANUFACTURER: Sentinel
DESIGNATION: 160-200-74
SIZE: 160
STRUCTURE: 200
STROKE: 74
SPM: Unknown
CEMENT PAD: Yes
BASE LENGTH: Unknown
GEARBOX S/N: SM2P4070
ASSEMBLED/DISASSEMBLED: Disassembled
Pumping Unit General Information
HORSEHEAD: Good
WALKING BEAM: Good
EQUALIZER: N/A
PITMAN ARMS: Good
CRANK ARMS: Good
T-BASE: N/A
UNIT ALIGNMENT: N/A
UNIT LEVEL: N/A
BELTS: N/A
JACKSHAFT: N/A
BELT GUARD: Fair
FENCE: N/A
UNIT BALANCE: N/A
WEIGHTS: None
Pumping Unit Brake System
ROD OR CABLE: Cable
ROD/CABLE CONDITION: Fair
BRAKE SHOES: External
SHOE CONDITION: Fair
BRAKE DRUM: Fair
BRAKE HANDLE: Fair
BRAKE CABLE: Unknown/Not Inspected
CARRIER BAR: Unknown/Not Inspected
SHAFT SIZE: Unknown/Not Inspected
GATE: Unknown
ROD ROTATOR: N/A
Pumping Unit Gear Box
RATIO: UnknownUnknown to 1
REDUCER SHEAVE: Unknown
OIL CAPACITY: Unknown
HIGH SPEED PINION: No Signs Of Wear
LOW SPEED PINION: No Signs Of Wear
HIGH SPEED GEAR: No Signs Of Wear
LOW SPEED GEAR: No Signs Of Wear
WIPERS: Unknown
HIGH SPEED SEALS: Not Seeping
GEARBOX SPLIT: Unknown
DRAIN VALVE CONDITION: Good
DRAIN VALVE FUNCTION: Not Seeping
Pumping Unit Bearing Assembly
WRISTPIN SEALS: Good,Not Seeping
WRISTPIN BEARINGS: Good,Not Seeping
SADDLE SEALS: Good,Not Seeping
SAMPSON POST SEALS: N/A,N/A
SAMPSON POST BEARINGS: N/A,N/A
TAIL SEALS: Good,Not Seeping
SADDLE BEARINGS: Good,Not Seeping
TAIL BEARINGS: Good,Not Seeping
COMMENTS for 160 Sentinel (E4): The item could not be operationally checked. Disassembled at time of inspection.